AHF Active Harmonic Filter

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2021-08-13 16:24
Browse the number: 221
inquiry
Company Profile
 
 
Product details

1.Product Description

CoEpower AHF Active Harmonic Filter is one product combining 3 functions: harmonic mitigation, power factor correction and three-phase unbalance correction. It has the capability to filter 2nd to 50th order harmonics and each order compensation ratio can be adjustable.AHF active harmonic filter module comes with a full range capacity from 15A to 150A. And for cabinet AHF active harmonic filter system, AHF can be infinite paralleled. When operating, AHF will output compensation current according to the harmonic current content in the system, no extra unwanted current injected to the syste


2,Product parameters

Rated Compensation

Current

25-150A in wall mounted

200-750A cabinet parallel configuration

Altitude Operating

Limit

1% up 2000m(2000-4000m)

The power decrease by 1% for every additional 100m

Rated Voltage(V)

220V/400V/480V/690V

Operating

temperature

-10℃ ~ +45℃/

Rated Frequency (Hz)

50HZ/60HZ

Relative

Humidity

≤95%,Non-condensing

Functions

1. Harmonic Compensation

2. Unbalance Correction

3. Power Factor Correction

Neutral Filtering

Capability

Yes

Network Configuration

3P4W

Noise Level

<60db

Parallel Operation

750A Per Cabinet

Or

Customized

CT Ratio

100;5~6000:5

Harmonic Compensation

Efficiency

>97%

Topology Design

3 Level

Harmonic Compensation

Capability

THDi<5%

Neutral Compensation

Capacity

3 times Rating

Harmonic Compensation

Range

2nd~50th Order

Monitoring

4.3 inch LCD Displayer

Or

Centralized Monitoring

Full response time

≤10ms

Power Loss

<3% Rated Power

IGBT Frequency

20KHz

Harmonic Spectrum

2nd~50th Harmonic Order

Protective function

16 Ways Protection

Design

Approoval

EN50065/60146/62477

IEC61000-4-2/5/6/4-12

IEC61000-6-4-2

Communication

Interface

RS485,Ehernet

Certificate

TUV CE/AS/URL

Communication

Protocol

MODBU S-RTU protocol



Model

30A/50A

        75A/100A

150A

Wall Mounted

Dimensions(mm)

423W*88D*550H                       503W*190D*597H

            503W*220D*598H

Rack Mounted

Dimensions(mm)

452.5W*450D*86H                    550.6W*540D*190H

            558W*540D*220H

Net Weight

14KGS

     34KGS /37KGS

                      44KGS

Protection Class

IP 20


3. Product feature

※ It has the functions reactive power compensation and three-phase imbalance control.According to different site requirements, it can flexibly adjust the function priority

※ The full response time is 10ms, which can keep the system in an ideal state with THDI less than 5%, PF reaching 0.99, and three-phase imbalance less than or equal to 3%

※ Can filter out 2 ~ 50 harmonics THDI < 5%, choose the harmonic order arbitrarily within this range, and adjust the filter output size to achieve the best filtering effect

※ Reactive power compensation range (-1 ~ 1). Capacitive and reactive power can be switched at any time. It can meet the reactive power compensation requirements of equipments such as stamping and welding with instantaneous reactive power changes.

※ Modular design for easy maintenance and installation. Supports two installation methods: rack- mounted and wall-mounted.

※ Independent air duct design, to ensure the equipment has good heat dissipation capability, and has a comprehensive temperature detection system, real-time detection of equipment temperature information

※ Perfect protection function, 16 kinds of protection functions, ensure equipment safety and system safety


4. Working Principle

External CT detects the load current, DSP tracksinstruction current and calculates the reactive power change rate through the Instantaneous Reactive Power Algorithm. Then DSP sends PWM signal to IGBT driving board which can control IGBT on and off to generate the same amplitude reverse compensation current. At the same time CT detects the output current and compensation result is fed back to DSP, then the next round of logic control is carried out to realize stable power grid.


5.Compensation effect

Unique intelligent FFT algorithm prevents system from resonance to assure stable.
3-Level structure and DSP/IGBT control get the 35kHz switching frequency and 5ms response time, less switching loss and faster response rate.




http://www.coepowers.com/